GUIDE
How research peptides are tested, and how to read a COA
A certificate of analysis (COA) is a lab report for one batch. A useful one names the batch, the lab, the test date, the methods and the results, and shows the chromatogram and spectrum behind them. Purity, identity, peptide content and endotoxin are separate tests. A high HPLC purity figure on its own does not tell you what is in the vial, or how much of it.
What a certificate of analysis is
A COA lists the tests a laboratory ran on a sample, the result of each one, the limit it was judged against, and whether the sample passed. It is usually prepared for each batch. The World Health Organization publishes a model COA for quality control laboratories, and its list is a good yardstick for any report.
A COA tells you about the sample that was tested. It only tells you about your vial if the two come from the same batch. That is why the batch number matters more than anything else on the page.
A credible COA shows:
- A batch or lot number that matches the label on the vial or pen.
- The product name, form and strength that were tested, such as a 10 mg freeze-dried vial.
- The name and address of the laboratory, and a report number on every page.
- The date the sample was received and the date it was tested.
- The method for each test, with its acceptance limit.
- Numerical results, with the HPLC chromatogram and the mass spectrum attached.
- A conclusion: did the sample meet its specification?
- The date and signature of the person who approved the report.
HPLC purity: what the percentage means
High-performance liquid chromatography (HPLC) separates a sample into its parts. A UV detector records each part as a peak. The purity figure is the area of the main peak as a share of the area of all the peaks.
So "99% purity" means that 99% of what the detector saw, under that method, came out as one peak. It does not prove that the peak is the right peptide. A wrong or substituted peptide can also give a clean single peak. That is why pharmacopoeial specifications for peptide medicines treat identification, purity and assay (content) as separate tests.
Purity is also only as good as the method. Impurities from peptide synthesis, such as chains with a missing or extra amino acid, are close in structure to the target peptide. They can be hard to separate and identify without more advanced methods. The FDA noted that most COAs it found for BPC-157 gave only a purity result, with no information on impurity limits.
Labels can be wrong. In a 2024 study, researchers bought semaglutide vials from illegal online sellers. The labels claimed 99% purity. Laboratory testing found 7.7% to 14.4%.
Mass spectrometry: is it the right molecule?
Mass spectrometry (MS) measures the mass of the molecules in a sample. It is how a lab checks identity: the measured molecular weight should match the expected weight for that peptide. For BPC-157 (free base), for example, the FDA gives a molecular weight of 1419.5 g/mol.
MS answers a different question from HPLC. HPLC asks how much of the sample is one thing. MS asks whether that thing has the right mass. A COA needs both. A purity figure with no mass spectrum leaves identity unproven.
Check the salt form too. The FDA treats BPC-157 free base and BPC-157 acetate as different substances, though both are sold as "BPC-157". The label and the COA should say which one you have. See our BPC-157 page.
Peptide content is not the same as purity
A freeze-dried peptide powder is never all peptide. Synthetic peptides are usually supplied as a salt, bound to a counter-ion such as trifluoroacetate (TFA) or acetate, and the powder also holds some water. Bachem, a peptide manufacturer, says the peptide content of the solid may be 70% to 90%.
Net peptide content is the share of the powder's weight that is peptide. Purity is the share of the peptide material that is the intended peptide. The two are not equivalent, and they are measured in different ways. Counter-ions do not show up in the purity figure: in one 2025 study, swapping TFA for chloride did not change the measured purity of the peptides tested.
So a vial labelled 10 mg at 99% purity can hold less than 10 mg of the peptide itself. Check whether the stated amount is the total fill or the net peptide content. In the 2024 semaglutide study, the measured amount in each vial did not match the label either.
The counter-ion can matter for research. TFA is left over from common synthesis and purification steps. A 1999 study found that TFA at very low concentrations reduced the growth of bone and cartilage cells in culture, and that the TFA salts of several peptides gave misleading results compared with other salts. Reviews of counter-ions note that they can change a peptide's physical properties and how it behaves in a formulation.
Endotoxin and sterility
These two tests matter for anything described as injectable, sold as a solution or filled into a pen. The FDA lists sterility, bacterial endotoxins and foreign particles as critical quality attributes for injectable products.
Sterility testing looks for living micro-organisms. Endotoxin testing looks for something different. Endotoxins are fever-causing substances from bacteria, and standard sterilisation does not remove them. So a product can be sterile and still contain endotoxin.
That is not only a theory. In the 2024 semaglutide study, the freeze-dried samples contained no viable micro-organisms, but endotoxin was found in every sample.
The usual endotoxin test is the LAL (Limulus amebocyte lysate) test, which uses blood cells from the horseshoe crab and reacts to endotoxin. The FDA has accepted it as a finished-product test for decades. A COA should give the result, usually in endotoxin units (EU) per mg or per vial, next to the limit it was tested against. "Pass" with no number and no limit tells you little.
Under US manufacturing rules, every batch of a medicine that claims to be sterile or pyrogen-free must be tested for it. Research peptides are not made under those rules, so the test is only there if the seller chose to run it and publish it.
Residual solvents and heavy metals
Peptide synthesis uses solvents, coupling reagents and scavengers, and traces can carry over into the final powder. Freeze-dried products typically contain trace residual solvents, which labs measure by gas chromatography. For licensed medicines, the international guideline ICH Q3C sets acceptable limits for each solvent.
Heavy metals, such as residues of metal catalysts, are covered by the guideline ICH Q3D on "elemental impurities". It asks makers of licensed medicines to assess the risk and set a control strategy to limit them.
Few research COAs include either test. In its BPC-157 review, the FDA found no information about residual solvent testing. A missing test is not proof of a problem, but it is a gap.
Third-party versus in-house testing
In-house testing is done by the manufacturer or the seller. Third-party testing is done by an independent laboratory with no stake in the result. Both can be honest. But an independent report is harder to fake, as long as you can trace it back to the lab.
The WHO model COA asks for the testing lab's name and address, and for any subcontracted tests to be marked as such. Where a trader re-issues a certificate, it should name the lab that did the tests and attach the original manufacturer's COA. Labs accredited to ISO/IEC 17025 should reference that accreditation on the report.
In our reviews we weight independent results above a brand testing its own product. See how we review.
How many listings show a COA? Our data
In our store listing pass of 13 November 2026, 3,191 of 6,690 product listings (48%) across 76 stores in the UK and South Africa showed a COA on the product page.
This counts whether a COA is shown on the page. It does not tell you whether the COA is batch-specific, independent or genuine. We do not lab-test products. We review stores from their public websites.
Source: Specktra store listing pass, 13 November 2026 (76 stores, 6,690 listings).
- UK: 2,999 of 4,245 listings (71%), at 20 of 33 stores. One store with a very large catalogue accounts for 2,355 of these listings and shows a COA on almost all of them. Without it, the UK figure is 661 of 1,890 listings (35%).
- South Africa: 192 of 2,445 listings (8%), at 9 of 43 stores.
- No store in either country showed a COA on every listing.
Red flags on a COA
A COA is a document, and documents can be copied or edited. These are the warning signs we look for:
- No batch number, or a batch number that does not match the vial.
- The same COA shown for several batches, strengths or products.
- A generic or "representative" COA not tied to any batch.
- A purity figure with no chromatogram, or an identity claim with no mass spectrum.
- A laboratory that cannot be found, has no address, or does not confirm the report.
- Signs of editing: mismatched fonts, blurred or pasted-in numbers, or dates that do not make sense.
- A test date years old, or a COA for a different form, such as a powder COA shown for a pen.
- "Third-party tested" on the page, with no report available.
Why pens and blends are harder to verify
A COA for the raw powder does not cover a finished pen or a blend. Once a peptide is dissolved, mixed with another peptide or filled into a cartridge, it is a new product. It has new ingredients, a new container and new steps where it can be contaminated or lose strength.
For licensed medicines, US rules require each batch of the finished product to be tested before release, including the identity and strength of each active ingredient. The WHO model COA likewise names the dosage form and strength of the sample tested. Apply the same standard to research products: the COA should cover the filled pen or the mixed vial, from the same batch you are buying.
For a blend, that means a result for each component, not one purity figure for the mix. For a pen or a solution, sterility and endotoxin results matter more, because the product is already in liquid form. The FDA also notes that peptides are sensitive to formulation and can form aggregates during storage, and that several analytical methods may be needed to detect them.
Storage matters too. See our guide to peptide storage and handling, and the glossary for the terms used here.
Frequently asked questions
Does 99% purity mean the vial is 99% peptide?
No. HPLC purity is the share of the peptide material that is the intended peptide. The powder also contains counter-ions such as TFA or acetate, and water. Net peptide content, the share of the weight that is peptide, may be 70% to 90%.
Is an HPLC result enough?
No. HPLC shows how much of the sample is one compound. It does not show which compound. Identity needs mass spectrometry, which checks that the molecule has the expected mass.
Why does endotoxin matter if a product is sterile?
Sterility means no living micro-organisms. Endotoxins are fever-causing substances from bacteria that standard sterilisation does not remove. A sterile product can still contain endotoxin, so the two need separate tests.
Does Specktra test peptides?
No. Specktra is a review site and does not sell or lab-test products. We review stores from their public websites, including whether they publish batch-specific COAs. See how we review.
How do I check that a COA is genuine?
Match the batch number to your vial. Check that the lab exists and has an address. Look for the chromatogram and mass spectrum. Where the lab offers it, ask it to confirm the report number. Treat a COA that fails any of these checks with caution.
Sources
- World Health Organization. Model certificate of analysis. WHO Technical Report Series No. 1010, Annex 4 (2018)
- Bachem. Quality control of amino acids and peptides: a guide (Knowledge Center)
- Bachem. Care and handling of peptides (Knowledge Center, January 2021)
- US FDA. Briefing document: BPC-157-related bulk drug substances, Pharmacy Compounding Advisory Committee meeting of 23–24 July 2026 (dated 11 May 2026)
- Vergote V et al. Quality specifications for peptide drugs: a regulatory-pharmaceutical approach. J Pept Sci 2009 PMID 19750489
- D'Hondt M et al. Related impurities in peptide medicines. J Pharm Biomed Anal 2014 PMID 25044089
- Ashraf AR et al. Multifactor quality and safety analysis of semaglutide products sold by online sellers without a prescription. J Med Internet Res 2024 PMID 39509151
- Cornish J et al. Trifluoroacetate, a contaminant in purified proteins, inhibits proliferation of osteoblasts and chondrocytes. Am J Physiol 1999 PMID 10567002
- Sikora K et al. The role of counter-ions in peptides: an overview. Pharmaceuticals (Basel) 2020 PMID 33287352
- Erckes V et al. Towards a consensus for the analysis and exchange of TFA as a counterion in synthetic peptides and its influence on membrane permeation. Pharmaceuticals (Basel) 2025 PMID 40872554
- Fennrich S et al. More than 70 years of pyrogen detection: current state and future perspectives. Altern Lab Anim 2016 PMID 27494624
- US FDA. Guidance for industry: pyrogen and endotoxins testing, questions and answers (Edition 2, March 2026)
- US Code of Federal Regulations, 21 CFR 211.165: testing and release for distribution
- US Code of Federal Regulations, 21 CFR 211.167: special testing requirements (sterile and pyrogen-free products)
- European Medicines Agency. ICH Q3C (R9) Residual solvents: scientific guideline
- European Medicines Agency. ICH Q3D Elemental impurities: scientific guideline
- Specktra store listing pass, 13 November 2026 (76 stores, 6,690 listings): UK 33 stores, 4,245 listings; South Africa 43 stores, 2,445 listings
FOR LABORATORY RESEARCH USE ONLY. NOT FOR HUMAN CONSUMPTION.
How we source and approve pages: editorial policy.